INSTALLATION
ASSEMBLY
INSTALLING HOSES
Risk of unsafe operation. Firmly grasp hose in hand when installing or
disconnecting to prevent hose whip.
1. Ensure Regulated Pressure Gauge (D) reads 0 psi.
2. Grasp the hose at the quick connect plug and push the plug into the quick connect body (E).
Coupler will snap into place.
3. Grasp the hose and pull to ensure coupler is seated.
DISCONNECTING HOSES
Risk of unsafe operation. Firmly grasp hose in hand when installing or
disconnecting to prevent hose whip.
1. Ensure Regulated Pressure Gauge (D) reads 0 psi.
2. Pull coupler on quick connect body back to release Quick Connect plug on hose.
GROUNDING INSTRUCTIONS (FIG. 2)
S
R
T
FIG. 2
Risk of Electrical Shock. In the event of
a short circuit, grounding reduces the risk of shock by
providing an escape wire for the electric current. This
air compressor must be properly grounded.
The portable air compressor is equipped with a cord
having a grounding wire with an
appropriate grounding plug.
1. The cord set and plug (R) with this unit contains a
grounding pin (S).
This plug MUST be used with a grounded outlet (T).
IMPORTANT: The outlet being used must be installed and grounded in accordance with all local
codes and ordinances.
2. Ensure the outlet being used has the same configuration as the grounded plug. DO NOT
USE AN ADAPTER.
3. Inspect the plug and cord before each use. Do not use if there are signs of damage.
4. If these grounding instructions are not completely understood, or if in doubt as to whether
the compressor is properly grounded, have the installation checked by a qualified electrician.
Risk of Electrical Shock. IMPROPER GROUNDING CAN RESULT IN ELECTRICAL
SHOCK.
• Donotmodifytheplugprovided.Ifitdoesnotfittheavailableoutlet,acorrectoutlet
should be installed by a qualified electrician.
• RepairstothecordsetorplugMUST be made by a qualified electrician.
EXTENSION CORDS
If an extension cord must be used, be sure it is:
• a3-wireextensioncordthathasa3-bladegroundingplug,anda3-slotreceptaclethatwill
accept the plug on the product
• ingoodcondition
• nolongerthan50feet(15.2m)
• 12gauge(AWG) or larger. (Wire size increases as gauge number decreases. 10 AWG and
8 AWG may also be used. DO NOT USE 14 OR 16 AWG.)
Risk of property damage. The use of an undersized extension cord will cause
voltage to drop resulting in power loss to the motor and overheating. Instead of using an
extension cord, increase the working reach of the air hose by attaching another length of hose