CHARGER OPERATION
NORMAL CHARGING:
• Plug the charger into a 120V AC outlet. Insert the battery pack onto
the charger ramp; press firmly to seat completely. The red indicator will
begin to flash and after a few seconds will light continuously. When the
charge is complete, the red indicator will go off and the green indicator
will come on. The battery pack can now be removed and installed in the
tool.
• Charge battery packs in a well-ventilated area. The charger housing has several ventilation openings.
These must remain open for proper charger operation. Do not obstruct these openings or place
charger on any surface that will block air from flowing through the charger housing. Do not cover the
charger or battery with a cloth or other cover while charging.
• The battery can be left on the charger after full charge has been reached. The battery will continue to
be charged at a low, trickle rate.
• If the CRN38 and battery packs are not going to be used within a week, battery life will be extended by
taking them off the charger. Recharge the battery packs before using again.
• Normal charging time is between 10 and 60 minutes. This will vary depending on the charge that is
needed. If the battery has only been partially discharged, the full 60-minute charge will not be
required.
• It is normal for the charger to hum and become warm to the touch during charging, this does not indi-
cate a problem.
FUNCTION OF CHARGER INDICATORS
• Flashing Red Indicator – when the battery pack is first placed on charger, it is being analyzed before
starting the Rapid Charge mode. Normally the indicator will change to steady red after a few sec-
onds, showing that rapid charging has begun. However, if the indicator continues flashing, the battery
pack may be too hot or may have been over discharged. Battery pack condition will be monitored and
the charger will switch to the Rapid Charge mode when ready. At that time, the steady red indicator
will be seen.
• Steady Red Indicator – the battery pack is in the Rapid Charge mode. Depending on the battery
pack condition, the charge mode will normally last up to one hour.
• Steady Green Indicator – the Rapid Charge mode has ended and the battery pack can be removed
for use in the tool. The battery pack can also be left in the charger and a small Trickle Charge current
will keep the battery pack fully charged.
SHINGLE GUIDE
SHINGLE GUIDE ADJUSTMENT
• Loosen locking screw using the 3mm wrench.
• Slide the guide to set the desired exposure 5" - 6 1/2"
• For longer exposure, remove the guide and reverse it.
• Tighten the locking screw.
IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL
OBSERVE THE FOLLOWING FOR SAFE OPERATION
• Use the STANLEY-BOSTITCH cordless tool only for the purpose for which it was designed.
• Never use this tool in a manner that could cause a fastener to be directed toward the user or
others in the work area.
• Do not use the tool as a hammer.
• Always carry the tool by the handle.
• Do not alter or modify this tool from the original design or function without approval from
STANLEY-BOSTITCH, INC.
• Always be aware that misuse and improper handling of this tool can cause injury to yourself
and others.
• Never clamp or tape the trigger in an actuated position.
• Never leave a tool unattended with the battery pack attached.
• Do not operate this tool if it does not contain a legible WARNING LABEL.
• Do not continue to use a tool that does not function properly. Notify your nearest Stanley-
Bostitch representative if your tool continues to experience functional problems.
-7-